Friday 11 November 2022 9.00am EST
During the last week the observing schedule was interrupted at 9:35am EST on Nov 6 by a trip of the on-board ACIS thermal monitor after the ACIS Digital Processor Assembly (DPA) temperature exceeded the trip limit. The safing monitor performed as designed and protected the electronics boards from exceeding thermal limits. The cause of the high DPA temperature was inaccuracy in the predictive thermal model used to plan the weekly loads. The model has been corrected to prevent a recurrence. Scheduled observations of B1152+199, TOI1535, ABELL 262 NE1, MAXI J1848-015, Gaia DR2 10025416171, and RBS0315 were impacted by the interrupt and will be rescheduled in future weeks. Real-time procedures were executed on Nov 7 to reactivate the ACIS Thermal Monitor and to re-enable SCS 107 before resumption of normal operations. Chandra passed through the 15th and 16th eclipses of the season on Nov 6 and 9 respectively, with nominal power and thermal performance. The schedule of targets for the next week is shown below and includes observations of MAXIJ1848-015, which was accepted as a Target of Opportunity on Oct 7 and is coordinated with VLA. |
------------------------------------------
MAXIJ1848-015 ACIS-S Nov 8 [GMV2015]ASW0009io9 ACIS-S MAXIJ1848-015 ACIS-S Abell2744 ACIS-I A399 ACIS-I Nov 9 Radiation Belts MAXIJ1848-015 ACIS-S B2.40229+23 ACIS-S MAXIJ1848-015 ACIS-S Nov 10 2MASSJ02121535+2357 ACIS-S MAXIJ1848-015 ACIS-S ABELL262NE2 ACIS-I PSZ2G049.18+65.05 ACIS-I M33 ACIS-S Nov 11 JWST-DTDF-1 ACIS-I Abell2744 ACIS-I A399 ACIS-I Radiation Belts Nov 12 WISEJ041010.60-0913 ACIS-S 2RXSJ223928.9-52052 ACIS-S WISEJ041010.60-0913 ACIS-S MRCB2223-528 ACIS-S Nov 13 WISEJ041010.60-0913 ACIS-S 2MASXJ21480531-5359 ACIS-S WISEJ041010.60-0913 ACIS-S
------------------------------------------
All spacecraft subsystems except HRC continued to support nominal operations.
Return to Status Reports